Minimally Invasive Anterior Femoral Knee Retractor

14-20 Days

$109.75

The Minimally Invasive Anterior Femoral Knee Retractor is a precision-engineered surgical tool designed to provide safe and stable retraction during minimally invasive knee arthroplasty and related orthopedic procedures. Its specialized design ensures controlled anterior femoral exposure while minimizing soft tissue trauma, making it an essential instrument for surgeons performing MIS total knee replacement (TKR) and ligament surgeries.

Crafted from premium German stainless steel, the retractor guarantees long-lasting durability, resistance to corrosion, and dependable performance in repeated surgical use. Its ergonomic structure and lightweight build enhance surgeon control and reduce fatigue, while the atraumatic blade edges protect surrounding tissues.

With a satin/polished finish, the instrument minimizes glare under operating lights, providing surgeons with optimal visibility. The retractor is fully autoclavable and reusable, ensuring cost-effectiveness for hospitals and surgical centers worldwide.

Certified under ISO 9001, ISO 13485 & CE, the Minimally Invasive Anterior Femoral Retractor meets international standards of surgical quality and safety, trusted by professionals globally.

Key Features:

  • Specially designed for MIS knee arthroplasty.

  • German stainless steel construction.

  • Ergonomic and lightweight for comfort.

  • Satin finish for reduced glare.

  • Autoclavable and reusable.

  • Certified: ISO 9001, ISO 13485 & CE.

The Minimally Invasive Anterior Femoral Knee Retractor is a vital instrument designed for modern minimally invasive knee surgery. Its purpose is to provide surgeons with precise control and exposure of the anterior femoral surface during procedures such as MIS total knee arthroplasty (TKA), ligament reconstructions, and trauma interventions.

With the increasing demand for less invasive techniques, retractors like this ensure patient safety, faster recovery, and reduced post-operative pain while enabling surgeons to maintain high accuracy during implant placement.


Clinical Applications

  • Minimally Invasive TKA (Total Knee Arthroplasty): Ensures safe retraction of soft tissues for proper visualization of the femur.

  • Ligament Reconstructions (ACL/PCL): Provides stable access to ligament insertion sites.

  • Knee Trauma Surgeries: Facilitates exposure for fracture fixation and reconstruction.

  • Sports Medicine Repairs: Allows clear access during minimally invasive ligament/tendon surgeries.

  • Revision Knee Procedures: Assists in retraction for complex re-operations.


Design Advantages

  • Optimized for MIS: Compact blade ensures retraction through smaller incisions.

  • Anterior Femoral Engagement: Specifically angled for controlled femoral exposure.

  • German Stainless Steel Build: Corrosion-resistant, strong, and long-lasting.

  • Ergonomic Handle: Reduces surgeon fatigue during lengthy procedures.

  • Atraumatic Blade Edges: Minimizes tissue trauma during retraction.

  • Satin Finish: Reduces glare from surgical lights for improved visibility.


Technical Specifications

  • Instrument Name: Minimally Invasive Anterior Femoral Retractor

  • Application: Knee surgery, MIS arthroplasty

  • Length: Standard surgical 9–10 inch range

  • Blade Width: Optimized for MIS exposure

  • Material: German stainless steel

  • Surface Finish: Satin / polished

  • Sterilization: Autoclavable & reusable

  • Certification: ISO 9001, ISO 13485 & CE


Benefits in Surgery

  • Provides precise retraction of anterior femoral tissues in MIS procedures.

  • Reduces patient trauma with atraumatic edges and compact design.

  • Enhances surgical accuracy and visualization.

  • Lightweight and ergonomic for surgeon comfort.

  • Reusable and easy to sterilize, ensuring long-term value.

  • Designed specifically for minimally invasive approaches where precision is critical.


Comparison with Similar Instruments

While standard retractors like the Blount Retractor or Langenbeck Retractor are used in broader orthopedic contexts, the Minimally Invasive Anterior Femoral Retractor is uniquely tailored for MIS procedures. Its blade size, angulation, and ergonomic design make it superior for limited-incision knee surgeries, offering advantages in patient recovery and surgical precision.


Care & Maintenance

  • Clean immediately after use with water to remove blood/debris.

  • Use neutral pH detergents in ultrasonic cleaning systems.

  • Sterilize in hospital-grade autoclaves.

  • Store securely to avoid bending or blade damage.

  • Inspect regularly for wear or corrosion before use.


Why Buy from Javeria Intl

  • Manufactured from premium German stainless steel.

  • Certified under ISO 9001, ISO 13485 & CE for global compliance.

  • Trusted worldwide by hospitals, clinics, and orthopedic surgeons.

  • Extensive catalog of orthopedic retractors and MIS instruments.

  • Competitive pricing without compromising quality.

  • Commitment to precision, innovation, and surgeon satisfaction.


Related Categories


Follow Javeria Intl Online


FAQs

Q1: What is the Minimally Invasive Anterior Femoral Retractor used for?
It is designed for controlled retraction of the anterior femur in minimally invasive knee arthroplasty and related surgeries.

Q2: What material is this instrument made from?
It is crafted from premium German stainless steel, ensuring durability and corrosion resistance.

Q3: Is the retractor reusable?
Yes, it is fully autoclavable and reusable, making it cost-effective for surgical centers.

Q4: Does it comply with international standards?
Yes, it is certified under ISO 9001, ISO 13485 & CE, ensuring global compliance.

Q5: Why choose Javeria Intl for MIS instruments?
Javeria Intl offers precision-engineered, certified, and surgeon-trusted instruments designed for modern minimally invasive techniques.

Reviews

There are no reviews yet.

Be the first to review “Minimally Invasive Anterior Femoral Knee Retractor”